Filter Results By:

Products

Applications

Manufacturers

Calibration References

A qualified quantified source of known value.

See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services


Showing results: 106 - 118 of 118 items found.

  • Sound Level Calibrator

    TM 100 - Kusam Electrical Industries Limited

    • Standard : Confirms to IEC 942 Class 1.• Output Sound Level : 94dB and 114dB under reference.• Accuracy : ±0.3dB (20°C, 760 mm Hg)• Frequency of 1000 ± 0.1% Hz allows calibration with A / B / C or D weighting networks or linear.• Low Battery Indicator (LED).- Operating Temperature range : -10 ~ +50 C- Storage Temperature range : -40 ~ +65 C (with batteries removed).- Temperature Coefficient : 0 ~ 0.01 dB / C• Calibration of “1 and ½” ceramic microphones.• Altitude Effects : Approx. 0.1 dB decrease for each 2000 feet increase in altitude fromsea level to 12,000 feet elevation, or comparable atmospheric pressure change(approx. every 50 mm of Hg decrease).• Battery : Single 9V transistor Battery. (NEDA 1604)• Battery Life : Approx 100 hours.• Dimension : 48 x 48 x 138mm

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 13.5 GHz

    S930901B - Keysight Technologies

    The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis For E5081A Up To 20 GHz

    S960904B - Keysight Technologies

    The Keysight S960904 spectrum analyzer (SA) software application adds high-performance spectrum analysis to the E5081A ENA-X up to 20 GHz. With fast-stepped FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The application enables simultaneous spectrum measurements using test and reference receivers. The multichannel SA pairs with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application uses source-power and receiver-response calibration and fixture de-embedding, providing highly accurate in-fixture and on-wafer spectrum measurements.

  • Fully Automatic Colorimeter

    DRK103C - Shandong Drick Instruments Co., Ltd.

    (1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.

  • Spectrum Analysis For E5081A Up To 44 GHz

    S960907B - Keysight Technologies

    The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine the multi-channel SA with the internal swept-signal generators. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Ion 700 Benchtop Meters

    OAKTON Instruments

    Oakton benchtop 700-series meters are designed for use in crowded laboratory settings. Compact footprint of less that 6" x 7" (16 x 18 cm) conserves valuable space, while the large, dual-display LCD provides excellent visibility—even from a distance. Ion 700 meter measures pH, mV, relative mV, ion concentration and temperature. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Models feature five-point pH calibration with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers. Meters additionally feature ion concentration calibration of up to 5 points. Meter features include Auto-Hold, selectable °F or °C measurement, and easy recall of electrode slope or offset. The convenient pull-out quick reference card keeps procedures handy at all times. Use 700-series meters with any pH, ORP, or ISE electrodes with a BNC connector.

  • 1.533 Μm Frequency-Locked Laser

    Thorlabs, Inc.

    Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.

  • Spectrum Analysis

    S95090B - Keysight Technologies

    The S95090B spectrum analyzer (SA) measurement software adds high-performance microwave spectrum analysis to PXI VNAs. With fast stepped-FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The S95090B software uses the PXI network analyzer's test and reference receivers to complete simultaneous spectrum measurements. Multi-channel SA measurements leverage the PXI VNA's internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The S95090B spectrum analyzer software application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy. Optional external attenuators should be connected with the VNA’s test ports to avoid receiver compression when measuring large signals.

  • pH & ORP Sensors

    Barben Analytical

    The Barben Analytical Performance Series products are 3rd generation combination pH/ORP electrodes targeted at harsh, industrial measurement applications. High pressures, strong chemicals, and elevated temperatures typically shorten the lifespan of conventional double-junction pH probes. In these applications the Performance Series sensor offers extended sensor lifespan, as well as decreased drift, and longer calibration intervals. Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High-Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations. A wide selection of sensor body styles and process fittings in a variety of corrosion resistant materials allow direct replacement of short-lived OEM pH/ORP sensors. Barben Performance Series sensors are compatible with all major manufacturers of pH analyzers and transmitters. Upgrade your analytical measurement without the hassle and expense of replacing costly field instruments.

  • Handheld Audio Analyzer

    PAA3X - Phonic Corporation

    The PAA3X is a highly accurate handheld audio analyzer that gives sound engineers a rich array of sound analysis tools. The system features both 61-band and 31-band real time spectrum analysis, RT60 reverb time measurement, SPL and line meter, internal signal generator, EQ setting program, microphone calibration and speaker phase checking abilities. All functions and menus can be accessed through a central jog dial, leaving your other hand free to adjust audio settings. The large color LCD screen has an adjustable brightness to help you see in a dark or well-lit environments alike. The PAA3X also features a "screen capture" function allowing users to save images of the screen to an SD card in BMP format for later reference. The detachable precision microphone can be placed remotely via the included 5-meter extension cable, offering flexible on-site operation management. With all this plus a built-in rechargeable lithium-ion battery, the PAA3X is a must-have multifunctional tool for all serious audio engineers.

  • Audio Test Software

    Soft Hearts LLC

    1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)

Get Help